Design heavy industrial central extraction: the dust composition
The first step in designing a filter is usually an analysis of the industrial dust. In cooperation with a reputable laboratory, a dust sample is analyzed. From this it becomes clear that there are several fractions of dust, but with the largest fraction being relatively coarse.
Large amounts of dust - switching filter
We then work with the customer to determine the specifications that the heavy-duty industrial central extraction system must meet.
In this case this was:
| Dust load | 600 kg/h |
| Flow rate | 30,000m3/h |
| Dust concentration input air | 20 g/Nm3 |
| Emission standard | < 0.1 mg/Nm3 |
1: Here the high dust load is particularly striking!
Return blowing of the filtered air into hallway
Another wish was to blow the air back into the hall. With a flow rate of 30,000 m3/h, this is a wise choice, so the warm air is reused in the winter. With the high gas prices of 2022, this quickly saves €100 – €150 per cold winter day!